What it means
Regenerations on bank 2 take longer than calibrated to complete - typically a low EGT during the cycle (cold weather, short trips) or a partially aged catalyst before the DPF.
At a glance
- Usually lights the check-engine light
- Affects emissions; the car can fail an emissions test
How it works
During regeneration, the bank 2 DPF heats up so trapped soot can burn away; the control module uses exhaust temperature and pressure data to track the cycle. This code sets when bank 2 regeneration takes longer than expected, often because the exhaust does not reach or maintain suitable temperature or the readings are inaccurate.
Common causes
Most likely first.
- Frequent short trips or low-load driving preventing regeneration temperatures
- Exhaust leak reducing temperature or affecting sensor readings
- Faulty exhaust temperature sensor or wiring
- Restricted DPF or deteriorated oxidation catalyst
Symptoms
- Check engine light or DPF warning light on
- Power loss / limp mode
- Increased fuel consumption
- Failed forced regeneration attempts
How to diagnose it
- Use a scan tool to review freeze-frame data, bank 2 regeneration duration and history, exhaust temperature readings, and DPF pressure.
- Check whether short trips, cold weather, or sustained low-load driving have kept the bank 2 exhaust too cool during regeneration.
- Inspect the bank 2 exhaust for leaks near temperature sensors and the oxidation catalyst, since leaks can affect heat and sensor readings.
- Check bank 2 exhaust temperature sensor connectors and wiring for damage, then compare cold and warmed-up readings for plausibility.
- If sensor readings are credible, compare DPF pressure and catalyst performance with the manufacturer's specification to identify a restricted filter or deteriorated oxidation catalyst.
Common fixes
- Repair an exhaust leak affecting bank 2 temperature or pressure readings.
- Repair damaged exhaust temperature sensor wiring or replace a confirmed faulty sensor.
- Correct driving or engine conditions that prevent bank 2 exhaust from reaching regeneration temperature.
- Clean or replace a restricted bank 2 DPF or service a deteriorated oxidation catalyst when testing confirms the fault.
Can I keep driving?
Avoid repeatedly interrupting a regeneration and arrange diagnosis if the warning persists or power falls. A bank 2 filter that cannot complete regeneration may accumulate more soot, increase fuel consumption, and eventually restrict exhaust flow.
A code shows where the control module detected a fault, not always which part failed. Check the causes in order and confirm with a test before replacing parts. Have several codes? Check them together
This is a generic code: it means the same on every make. The car’s maker may add more detail in its own service information.